First-generation intelligent integrated cabinet
Product Categories:
Complies with international standard ISO 12944, Data Center Design Code (GB 50174-2017), Integrated Cabling System Engineering Design Code (GB/T 50311-2016), Building Fire Protection Code (GB 50016-2014), General Specifications for Computer Room Sites (GB/T 2887-2000), Technical Code for Security Prevention Engineering (GB 50348-2018), Architectural Lighting Design Standard (GB 50034-2013), Flame-retardant and Fire-resistant Flexible Cables for Communication Power Supplies (YD/T 1173-2016), and Design Code for Lightning Protection and Earthing Engineering of Telecommunication Bureaus (Stations) (YD 5098-2005).
It also complies with the safety requirements for information technology equipment specified in GB 4943.1 and GB 4943.23, as well as the general tolerance requirements for linear and angular dimensions where no tolerances are indicated (using the m grade according to GB/T 1804), and the requirements for form and position tolerances where no tolerance values are specified (using the K grade according to GB/T 1184), among others.
Product Details
Product Overview
The intelligent integrated data center is designed in accordance with data center standards and integrates modules such as cooling, power distribution, monitoring, UPS and battery systems, and structured cabling, thereby forming a cabinet-level intelligent micro-data center that provides a secure and stable operating environment for IT equipment. It serves as a compact, standalone version of a traditional data center.
Specifications and Parameters
| Project | Description | Single cabinet | Cabinet arrangement (supports up to 1 master unit and 7 slave units) |
|---|---|---|---|
| Overall parameters | Power supply standard | 220Vac, 380Vac | |
| Work environment | 0~40℃ | ||
| Altitude | 0–4,000 m (derated operation above 2,000 m) | ||
| Cabinet System | Cabinet dimensions (width × height × depth) | 600×2000×(1200–1400) mm | (600–4200) × 2000 × (1200–1400) mm |
| Distribution System | Input main switch | 32A/63A | 32A/63A/100A/200A/250A |
| Output circuit | UPS input, UPS output, UPS bypass, PDU output, cooling output, etc.; 16 A to 100 A | ||
| UPS capacity | 3KVA/6KVA | 6 kVA ~ 30 kVA | |
| UPS Configuration | Single UPS | Single/Double UPS | |
| Power factor | ≥0.9 | ||
| Efficiency | ≥94% | ||
| Backup power | Lead-acid battery packs, lithium battery packs, battery racks, and battery cabinets | ||
| Refrigeration system | Rack-mounted air conditioner | 3.5 kW / 4.2 kW / 8.1 kW / 12.5 kW cooling; N+1 redundancy; Outdoor: -40°C to 45°C; Indoor: 18°C to 40°C; Inverter-driven EC compressor with indoor and outdoor fans; quick-connect fittings—no soldering required. |
|
| Surveillance system | Monitoring function | 10.1-inch touchscreen; monitoring of power distribution, UPS, batteries, temperature and humidity, smoke, water leakage, access control, and more; Supports system management, real-time data, and historical data. |
|
| Optional Components | Component Name | Smart access control, SMS alerts, video surveillance, low-temperature components, air-conditioning extension modules, centralized management platform, ATS module, and more. | |
Application Scenarios
Product Features
Safe and reliable
- Unattended design
- IP5X protection rating
Rapid Deployment
- Factory-Prefabricated Modular
- Supports custom scaling
Low investment
- Reduce capital and time costs
- Space savings ≥ 50%
- No data center renovation required.
Highly integrated
- Integrated cabinet, cooling, power distribution, fire protection, and monitoring
Comprehensive monitoring
- Real-time Operation Monitoring
- Centralized management of multiple outlets
Energy-saving and quiet
- Low PUE
- Noise ≤ 55 dB
Form of expression

Key Technology: Microenvironment Monitoring
Comprehensive monitoring of UPS systems, battery banks, power distribution, HVAC, temperature and humidity, smoke detection, and water leakage, with support for 3D visualization and multi-device access via PC, mobile, and dedicated apps, ensuring 24/7 operation and multi-channel alerting.

Key Technology · Energy Conservation