CN EN ES AR PT FR
Back

Category

Product Categories

Second-generation intelligent integrated cabinet

Complies with international standard ISO 12944, Data Center Design Code (GB 50174-2017), Integrated Cabling System Engineering Design Code (GB/T 50311-2016), Building Fire Protection Code (GB 50016-2014), General Specifications for Computer Room Sites (GB/T 2887-2000), Technical Code for Security Prevention Engineering (GB 50348-2018), Architectural Lighting Design Standard (GB 50034-2013), Flame-retardant and Fire-resistant Flexible Cables for Communication Power Supplies (YD/T 1173-2016), and Design Code for Lightning Protection and Earthing Engineering of Telecommunication Bureaus (Stations) (YD 5098-2005). It also complies with the safety requirements for information technology equipment specified in GB 4943.1 and GB 4943.23, as well as the general tolerance requirements for linear and angular dimensions where no tolerances are indicated (using the m-grade tolerance class per GB/T 1804), and the requirements for form and position tolerances where no tolerance values are specified (using the K-grade tolerance class per GB/T 1184).

Product Details

Product Overview

A compact, modular data center solution designed for edge computing and branch offices. Featuring a highly integrated design, it consolidates power distribution, UPS, monitoring, cooling, server cabinets, fire suppression (optional), and security systems into a single, unified platform, significantly reducing the required floor space. Prefabricated at the factory and ready to plug-and-play, it enables rapid deployment and remote operations and maintenance.
Single-row modular design with enclosed hot and cold aisles for enhanced energy efficiency. Rack-mounted UPS combined with power distribution modules delivers a compact, safe, and reliable architecture. An efficient power and cooling system ensures stable operation.
Integrates power distribution, UPS, monitoring, cooling, cabinet, and security systems. Supports rapid capacity expansion and intelligent management, reducing operational and maintenance complexity.

Specifications and Parameters

Project Description Single cabinet Cabinet arrangement (supports up to 1 master unit and 7 slave units)
Overall parameters Power supply standard 220Vac, 380Vac
Work environment 0~40℃
Altitude 0–4,000 m (derated operation above 2,000 m)
Cabinet System Cabinet dimensions (width × height × depth) 600 mm × 2000 mm × (1200–1400) mm (600–4200) mm × 2000 mm × (1200–1400) mm
Distribution System Input main switch 32A/63A 32A/63A/100A/200A/250A
Output circuit UPS input, UPS output, UPS bypass, PDU output, cooling output, etc.; 16 A to 100 A
UPS capacity 3KVA/6KVA 6 kVA ~ 30 kVA
UPS Configuration Single UPS Single/Double UPS
Power factor ≥0.9
Efficiency ≥94%
  Backup power Lead-acid battery packs, lithium battery packs, battery racks, and battery cabinets
Refrigeration system Rack-mounted air conditioner 3.5 kW / 4.2 kW / 8.1 kW / 12.5 kW; N+1 redundancy; outdoor operating range: -40°C to 45°C; indoor operating range: 18°C to 40°C; inverter-driven compressor; quick-connect fittings—no soldering required.
Surveillance system Monitoring function 10.1-inch touch screen, supporting monitoring of power distribution, UPS, batteries, temperature and humidity, smoke, water leakage, access control, and more; supports real-time and historical data management.
Optional Components Component Name Smart access control, SMS alerts, video surveillance, low-temperature components, air-conditioning extension modules, centralized management platform, ATS module, and more.

Application Industries

Government education and healthcare enterprises Communications, Transportation, Finance, and Military Industry 

Integrated Monitoring System

Monitoring Platform

Map Display

Supports image/GIS map display

Equipment Management

Device Status/IP/Online Statistics

Mobile app

Remote Viewing and Control

Permission Management

Regional Permission Management

Real-time monitoring

3D Condition Monitoring

Fault Management

Alarm Statistics and Analysis

Alert Notification

Multi-mode alarm

Large-screen display

Chart-based visualization

B/S architecture · High reliability · Low latency · High concurrency

Product Features

Safe and reliable

  • Unattended design
  • IP5X protection rating

Rapid Deployment

  • Factory prefabrication
  • Modular scaling

Low investment

  • Reduce funding costs
  • Space savings ≥ 50%
  • No data center renovation required.

Highly integrated

  • System-wide integration

Comprehensive monitoring

  • Real-time Operation Monitoring
  • Multi-site management

Energy-saving and quiet

  • Low PUE
  • Noise ≤ 55 dB

Product Showcase

Single cabinet / 1–3 cabinet combination

4-5 cabinet combination

6-7 cabinet combination

Keywords:

Previous page

Next page

More recommendations

Second-generation intelligent integrated cabinet

F8

ZP Rack Dedicated for Hot and Cold Aisle

WS

Intent Information

Submit a message